Engrove Audio Lab

Record centering

Concept simulator
Ready

Ready to measure

0 / 180 sector samples
Platter
Sector angle
X motor
Y motor
Contacts
Elapsed

Platter & tonearm

Chassis frame
+ Rotation axis Groove centerOffset ×32

XY drive

Platter frame
XY drive schematicTop view in platter coordinates. The X motor sits on the base. The Y motor rides on the X carriage. Marks on the couplings and dials show rotation. X carriage Y carriage / glass X motorFlexible couplingX micrometerStage baseY motorY micrometer +X+Y Slip contacts in section X pairY pair
X0° · 0 µm Y0° · 0 µm

Groove center

Groove center relative to the rotation axisPlatter coordinates. X points right and Y up. The green circle marks tolerance. Dashed lines show probe motion or slip. IIIIIIIV +X+Y0
Model position

Drag the point or enter X and Y. Maximum starting radius is 2,500 µm.

○ Start● Model◇ Sensor estimateDashed line · probe
Rolling estimate—
Last block—
XY command—

P1 angle sensor

AS5047P · 14 bit
Absolute P1 angle— °— / 16383
Relative angle— °
0°
Peak-to-peak · last revolution— °Awaiting reference

P1 vs. platter angle

Sector samples During pulse Last block

Motor & sensor timing

Sector readings Block samples0 samples during XY

Pulse timing

Model settings

Next run settings

Platter & sampling

XY drive

Tonearm & sensor

Ten-angle trial

Ten runs, 36° apart, share settings and initial calibration. Each uses its own noise seed. Replay any run at the selected speed.

No trials yet.
Results by starting angle
TrialAngleSensor, µmModel, µmTime, sX pulsesY pulsesXY pulsesOutcomeReplay

Event log

0 events

Pulse numbers link each command to the readings before and after it.

    How the model works

    The mechanism diagrams are schematic. All readings are simulated.

    During playback the stylus follows a simulated spiral from 110 to 60 mm. Pitch can vary over 48 revolutions. The controller fits local feed plus once-per-revolution sine and cosine terms to P1 samples. Centering uses the fitted periodic component.

    The lamp lights after two blocks above tolerance, allowing for noise. Press Center to request adjustment. The current block confirms the need before motor start. Two good blocks with raised contacts verify the correction while the stylus follows the groove. The model assumes constant local P1 sensitivity and excludes audio, tracking force and groove jumps.

    A subplatter reference provides 60 sectors at 6° intervals. The arm pivot stays fixed while the XY axes rotate with the record. A 200 µm offset at 45° gives about +141 µm on each axis.

    The AS5047P model quantizes P1 to 14 bits. It samples at 120 Hz and at each sector boundary, sharing coincident readings. The angle chart shows deviations in degrees or µm. Each measurement block fits sine and cosine over full revolutions with equal sector spacing.

    Known geometry resolves X and Y using the chosen phase (28° by default) and nominal screw feed. Probe calibration measures direction and average feed with +X then +Y pulses. Calibration can be reused during this visit. P1 keeps sampling during motion. The rolling estimate advances earlier samples using the commanded feed.

    Before the first block, P1 uses the first raw sample as its reference. It then uses the latest block mean. Peak-to-peak includes noise across 60 sectors. JSON records settings, seed, calibration, events, blocks and pulses. CSV records each 6° crossing, raw code, P1 angle and motor commands. Both exports work mid-run.

    After each pulse the model allows 0.18 s to settle while rotation continues. Two separate blocks at playback speed must meet tolerance including the noise margin, with contacts raised. A borderline block can be extended. The model stops after 32 corrections or three failed final checks.

    The default P1 sensitivity of 0.425°/mm and mechanical settings are examples. Use measured sensitivity at the test groove radius. Each screw has ±6.5 mm travel and a 22 ms start delay. Y feeds at 96% of nominal X speed. Elastic loading precedes breakaway. A synchronous disturbance can produce a false pass, visible in the ten-angle trial.

    Block residuals determine the noise margin. Repeated identical sector codes also carry a quantization margin. The locked groove is assumed circular. AS5047P datasheet ↗